Welcome to Jiangsu Chenzhou Environmental Protection Technology Co., Ltd.!

Thermal spraying oxygen eliminator
 
Main technological parameter
Working pressure and temperature: 0.02MPa     104℃
Water softening pressure and temperature: 0.2 MPa      >20℃
Steam pressure and temperature: 0.33 MPa     145℃
Oxygen content: ≤0.03mg/L
Activated pressure of safety valve: 0.06 MPa
 
Equipment parameter

 

     Model
Item
KP10
KP20
KP35
KP50
KP70
KP100
KP150
maximum output (T/H)
11
22
40
56
78
106
160
water tank volume (m3)
6.4
12
20
30
40
40
50
diameter of deoxygenization head Φ
600
800
1000
1200
1400
1500
1600
diameter of water tank Φ
1600
2000
2400
2800
3000
3000
3000
L1
5000
5500
6000
6500
8250
8250
8600
L2
1900
2300
2700
3100
3300
3300
3300
L3
3800
4200
4600
5800
6500
6680
6820
F
1850
3150
2200
2860
3162
3162
3250
G
500
550
610
780
980
1090
1150
Z
1100
1200
1700
1700
1726
1726
1726
A
350
400
400
450
450
450
450
B
1400
1800
2200
2600
2600
2650
2650
C exhausting
1200
1400
1500
1600
1750
1755
1850
exhausting DN1
40
40
50
50
80
80
80
condensation water inlet DN2
40
40
50
50
80
80
100
feeding water inlet DN3
80
80
100
125
150
150
150
steam inlet DN4
100
150
150
150
200
200
200
feed pump backflow DN5
80
80
100
125
150
200
200
vapor equilibrium DN6
100
125
150
150
200
200
200
delivery port DN7
100
125
150
150
200
200
200
secondary steam DN8
50
65
80
100
100
100
150
pollution discharge of water tank DN9
65
65
80
100
100
100
150
water balance DN10
100
125
150
200
200
200
200
BACK